Page 1 ABX Micros ES60 User manual P/n: RAB237AEN Explore the future.; Page 3 ABX MICROS ES60 OT/CT User Manual P/n: RAB237AEN HORIBA ABX SAS B.P. 7290 34184 MONTPELLIER Cedex 4 - FRANCE.; Page 4 When a subsequent software version is released, only the electronic version (CD-ROM and/or online help) of this user manual is updated and supplied by HORIBA ABX. Horiba Medical - ABX Pentra 400 The ABX Pentra 400 is an extremely compact Clinical Chemistry benchtop analyzer. Its automation and continuous loading provide. Hematology Analyzer ABX Micros 60® CLIA Moderate Complexity Horiba McKesson Shop Products Shop by Category. Horiba #; Hematology Analyzer ABX Micros 60® CLIA Moderate Complexity M60 SYSTEM, CT16P W/BC D/S. Analyzer, Laser Printer, Barcode Reader, User Manual, Spare Parts Kit, Tool Kit, Complete Set of Reagents.
One moment please..
Horiba Medical - ABX Micros CRP 200
|
1Reply3 years ago |
3 years agoMaintenance MICROS CRP 200
error E5 on MICROS CRP 200 T c helicon talkbox synth users manual.
Reply
|
FEATURES
Horiba Micros 60 User Manual
WBC, RBC and PLT : ImpedanceHGB : Spectrophotometry (Cyanmethemoglobin method)HCT : Numeric integrationCRP : Latex immuno turbidity rate methodMCV, MCH, MCHC, RDW, MPV, PCT* and PDW*.Calculations.
Additional Specifications
Horiba Abx Micros 60 User Manual Pdf
Technical
Power requirement
Power supply from 100 Vac to 240 Vac +/- 10%
50 Hz to 60 Hz.
Power consumption Maximum 230 VA.
Operating Temperature and Humidity : 18°C - 30°C (64°F-86°F) room temperature.
Maximum relative humidity 80% for temperature up to 31°C (88°F) decreasing linearly to 50% relative humidity at 40°C (104°F).
Dimensions and Weight
Weight : 40 lbs.
Dimensions : W 11.8 x H 16.7 x D 15.7 in
Memory
QC (CBC) and QC (CRP) modes: 30 samples
CBC and CBC+CRP modes: 50 samples
Samples
Parameters
CBC mode 18 parameters with graphics for RBC, PLT and WBC populations.
RBC, WBC, PLT, HGB, HCT, MCV, MCH, MCHC, PCT, MPV, PDW, RDW, Lymphocytes (% and #), Monocytes (% and #), Granulocytes (% and #).
CBC & CRP mode 18 parameters & CRP
Sample-Volume
CBC mode : 10 µl
CBC & CRP mode : 18 µl
Measurement item
WBC, RBC, HGB, HCT, PLT, CRP (C-reactive protein) MCV, MCH,
MCHC, RDW, MPV, LYM%, LYM#, MON%, MON#, GRA%, GRA#, PCT*, PDW*.
Sample processing
On open tube with 4 position tube holder (QC, 500 µL, 3 mL, 5 mL)
Throughput analyses
CBC mode: Within 1 min, 15-sec (48 samples/hour)
CBC + CRP mode: Within 4min, 30-sec (14 samples/hour)
*: RUO parameters (Research Use Only)
Power requirement
Power supply from 100 Vac to 240 Vac +/- 10%
50 Hz to 60 Hz.
Power consumption Maximum 230 VA.
Operating Temperature and Humidity : 18°C - 30°C (64°F-86°F) room temperature.
Maximum relative humidity 80% for temperature up to 31°C (88°F) decreasing linearly to 50% relative humidity at 40°C (104°F).
Dimensions and Weight
Weight : 40 lbs.
Dimensions : W 11.8 x H 16.7 x D 15.7 in
Memory
QC (CBC) and QC (CRP) modes: 30 samples
CBC and CBC+CRP modes: 50 samples
Samples
Parameters
CBC mode 18 parameters with graphics for RBC, PLT and WBC populations.
RBC, WBC, PLT, HGB, HCT, MCV, MCH, MCHC, PCT, MPV, PDW, RDW, Lymphocytes (% and #), Monocytes (% and #), Granulocytes (% and #).
CBC & CRP mode 18 parameters & CRP
Sample-Volume
CBC mode : 10 µl
CBC & CRP mode : 18 µl
Measurement item
WBC, RBC, HGB, HCT, PLT, CRP (C-reactive protein) MCV, MCH,
MCHC, RDW, MPV, LYM%, LYM#, MON%, MON#, GRA%, GRA#, PCT*, PDW*.
Sample processing
On open tube with 4 position tube holder (QC, 500 µL, 3 mL, 5 mL)
Throughput analyses
CBC mode: Within 1 min, 15-sec (48 samples/hour)
CBC + CRP mode: Within 4min, 30-sec (14 samples/hour)
*: RUO parameters (Research Use Only)
Comments are closed.